ELAN HOME SYSTEMS
INSTALLATION MANUAL
Page 14 © ELAN Home Systems 2002 • All rights reserved. 3/02
3.3 CREATING
ZONES WITH
SUB-Z
ONES
The dip switches located on the front of the Z•630 enable
you to easily configure zones with sub-zones. When
moved to the UP position, these zone-specific dip switches
disable the VOLUMEUP/VOLUME DOWN buttons on the
keypad and independently “FIX” the output level for each
zone at maximum.
SUB-ZONE C
ONTROL
When the dip switches are in the DOWN or “VARIABLE”
position, pressing VOLUME UP/VOLUME DOWN on the
keypad would not only raise or lower the volume in the
main zone, but would also affect the volume levels in other
rooms that are a part of that zone (sub-zones).
Should the volume on a keypad be turned all the way
down, no level would be available at any of the sub-zone’s
volume controls. By setting the output level to FIXED,
audio will always be present at the volume controls. This
configurations does, however, require that a volume
control be installed in the main zone as well.
In this scenario below, Zone 1 is a stand-alone; Zone 2 is
a stereo zone with a stereo sub-zone; and Zone 3 is a
mono zone with three mono sub-zones. Note that the dip
switches for Zones 2 and 3 have been moved to the UP or
“FIXED” position.
Make sure to maintain proper impedance loads at the amplifier.
In this diagram, Zone 2 would require impedance matching
stereo volume controls set at 2x, and Zone 3 would require
impedance matching mono volume controls set at 2x (assum-
ing all speakers are 8 ohms).
NOTE: Set Dip Switches 2 and 3
to the UP position to FIX the line
outputs of zones 2 and 3
Y - Cord
Figure 3.3 - A three zone system utilizing volume controls in the sub-zones.